DC Electronic Loads
Our wide selection of DC loads start at tens of watts, increasing in to the megawatt range. Each unit precisely simulates the loading of a circuit. Load profiles are programmable for voltage, current and power.
Common operating features throughout the range include OVP/OCP tests, front panel memory as well as CC, CV, CR and CP modes. Rise, fall and plateau times are adjustable in dynamic mode. Your chosen load can also be built with analogue and computer interfaces for remote operation. LabVIEW drivers are available for most product families to simplify integration into wider systems.
When compared to a traditional resistive load bank, a programmable electronic load offers superior functionality. Sink values of selected models can be adjusted in small increments into the milliamp range, under a variety of waveforms. In contrast, a resistive load bank typically doesn't have the programmability required to recreate real world load profiles.
All of our dynamic DC loads are available with a current waveform generator. This allows real world load profiles to be created on a PC using waveform generator software which is particularly useful to qualify product designs, check production batches and repair electronics. The loads can also be made to follow complex waveforms by tracking an external arbitrary oscillator input.
Where precision is key, an advanced function generator is available for G5-REGEN and ELP-GXS power recycling loads. Complex custom waveforms can be plotted against time for discharging batteries, fuel cell loading and testing DC power supplies. Application GUIs for emulating the characteristics of batteries and capacitors are available. Multi-module systems can configured up to 3000V/2MW.
Read more CloseDid you know...
- Our bidirectional systems operate as both a DC load and a DC source.
- Wide ranging ELP-34360 models can sink their full 600A nominal current from 1000V all the way down to 20V without derating.
- Flight case integrations are available for all rackmounting products. For more information contact us.
G5-REGEN
Modular Regenerative DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 18kW | 0 to 6MW This maximum is achieved by using units in master-slave. |
Voltage: | 3 to 500VDC | 16 to 3000VDC Configurations >1500V are possible with a centre tapped earth. |
Current: | 0 to 54A | 0 to 19440A This maximum is achieved by using units in master-slave. |
G5-REGEN
Modular Regenerative DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 18kW | 0 to 6MW This maximum is achieved by using units in master-slave. |
Voltage: | 3 to 500VDC | 16 to 3000VDC Configurations >1500V are possible with a centre tapped earth. |
Current: | 0 to 54A | 0 to 19440A This maximum is achieved by using units in master-slave. |
Standard Control: | Analogue, Ethernet, USB |
---|---|
Optional Control: | Touchscreen HMI, CAN, EtherCAT |
With the ability to sink DC power up to high voltage and currents, the G5-REGEN is ideal for testing energy storage devices. Modules are stackable to 2MW, with voltages up to 3000V possible.
G5-REGEN-HC
Modular High Current DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 9kW | 0 to 6MW This maximum is achieved by using units in master-slave. |
Voltage: | 1 to 80VDC | 16 to 1280VDC Configurations >640V are possible with a centre tapped earth. |
Current: | 0 to 338A | 0 to 121680A This maximum is achieved by using units in master-slave. |
G5-REGEN-HC
Modular High Current DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 9kW | 0 to 6MW This maximum is achieved by using units in master-slave. |
Voltage: | 1 to 80VDC | 16 to 1280VDC Configurations >640V are possible with a centre tapped earth. |
Current: | 0 to 338A | 0 to 121680A This maximum is achieved by using units in master-slave. |
Standard Control: | Analogue, Ethernet, USB |
---|---|
Optional Control: | Touchscreen HMI, CAN, EtherCAT |
With the ability to sink DC power up to high currents, the G5-REGEN-HC is ideal for testing low voltage energy storage devices. Modules are stackable to over 2MW, with current to over 89kA possible.
ELP-GXS
Modular Regenerative DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 20kW | 0 to 2MW This maximum is achieved by using units in master-slave. |
Voltage: | 6 to 65VDC | 40 to 1500VDC This maximum is achieved by using units in master-slave. |
Current: | 0 to 40A | 0 to 38400A This maximum is achieved by using units in master-slave. |
ELP-GXS
Modular Regenerative DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 20kW | 0 to 2MW This maximum is achieved by using units in master-slave. |
Voltage: | 6 to 65VDC | 40 to 1500VDC This maximum is achieved by using units in master-slave. |
Current: | 0 to 40A | 0 to 38400A This maximum is achieved by using units in master-slave. |
Standard Control: | Analogue, RS-232 |
---|---|
Optional Control: | HMI, CAN, Ethernet, IEEE 488.2, Optolink, RS-422, USB |
The ELP-GXS regenerates energy back to the grid instead of wasting it as heat. Modules can be combined in parallel, series and matrix configurations to high powers/voltages. An optional function generator allows virtually any DC waveform to be created.
ELP-HIVOLT
High Voltage High Power DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 480kW This maximum is achieved by using units in master-slave. |
Voltage: | 55 to 1250VDC | 55 to 1250VDC |
Current: | 0 to 25A | 0 to 2400A This maximum is achieved by using units in master-slave. |
ELP-HIVOLT
High Voltage High Power DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 480kW This maximum is achieved by using units in master-slave. |
Voltage: | 55 to 1250VDC | 55 to 1250VDC |
Current: | 0 to 25A | 0 to 2400A This maximum is achieved by using units in master-slave. |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
Standard operating features include OVP & OCP tests, dual voltage and current ranges, 150 state memory as well as CC, CV, CR and CP modes. Rise, fall and plateau are adjustable in dynamic mode. Dedicated short circuit, OCP and OPP tests are provided.
ELP-34305
Dual Range High Voltage DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 480kW This maximum is achieved by using units in master-slave. |
Voltage: | 30 to 1000VDC | 30 to 1000VDC |
Current: | 0 to 50A | 0 to 4800A This maximum is achieved by using units in master-slave. |
ELP-34305
Dual Range High Voltage DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 480kW This maximum is achieved by using units in master-slave. |
Voltage: | 30 to 1000VDC | 30 to 1000VDC |
Current: | 0 to 50A | 0 to 4800A This maximum is achieved by using units in master-slave. |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
This precision series features dual setting and measurement ranges, combined with a 5 digit display for high resolution. Adjustable rise, fall and plateau times in dynamic mode are ideal for testing photovoltaic cells and high voltage batteries.
ELP-34205
High Current 600VDC Electronic Loads
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 480kW This maximum is achieved by using units in master-slave. |
Voltage: | 20 to 600VDC | 20 to 800VDC Different nominals can be selected via the options table. |
Current: | 0 to 160A | 0 to 10240A This maximum is achieved by using units in master-slave. |
ELP-34205
High Current 600VDC Electronic Loads
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 480kW This maximum is achieved by using units in master-slave. |
Voltage: | 20 to 600VDC | 20 to 800VDC Different nominals can be selected via the options table. |
Current: | 0 to 160A | 0 to 10240A This maximum is achieved by using units in master-slave. |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
Wide voltage and current ranges make the ELP-34205 an excellent general purpose DC load. Commonly used load set-ups can be easily and quickly saved and recalled from the front panel. Dedicated short circuit, OCP and OPP tests are provided.
ELP-34105
Compact High Current DC Load
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 320kW This maximum is achieved by using units in master-slave. |
Voltage: | 0.7 to 60VDC | 0.7 to 60VDC |
Current: | 0 to 1000A | 0 to 8000A This maximum is achieved by using units in master-slave. |
ELP-34105
Compact High Current DC Load
Min | Max | |
---|---|---|
Power: | 0 to 5kW | 0 to 320kW This maximum is achieved by using units in master-slave. |
Voltage: | 0.7 to 60VDC | 0.7 to 60VDC |
Current: | 0 to 1000A | 0 to 8000A This maximum is achieved by using units in master-slave. |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
This range is comprised of 8 models from 5kW to 40kW. All units can operate in CC, CV, CR, CP, CV+CC, CV+CP, MPPT, dynamic and short modes. 150-state front panel memory is provided as standard. The current slew rate is adjustable.
ELP-34000C
Advanced DC Electronic Loads
Min | Max | |
---|---|---|
Power: | 0 to 6kW | 0 to 192kW This maximum is achieved by using units in master-slave. |
Voltage: | 0.7 to 150VDC | 15 to 1200VDC |
Current: | 0 to 24A | 0 to 1600A This maximum is achieved by using units in master-slave. |
ELP-34000C
Advanced DC Electronic Loads
Min | Max | |
---|---|---|
Power: | 0 to 6kW | 0 to 192kW This maximum is achieved by using units in master-slave. |
Voltage: | 0.7 to 150VDC | 15 to 1200VDC |
Current: | 0 to 24A | 0 to 1600A This maximum is achieved by using units in master-slave. |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
This range is comprised of various models from 150V up to 1200V, at a number of different power nominals. Units are stackable up to 192kW in master/slave. Each DC load has 9 different operating modes and a 150-state front panel memory.
ELP-3360PF
High Voltage High Power DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 7.2kW | 0 to 14.4kW |
Voltage: | 4 to 500VDC | 4 to 500VDC |
Current: | 0 to 60A | 0 to 500A |
ELP-3360PF
High Voltage High Power DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 7.2kW | 0 to 14.4kW |
Voltage: | 4 to 500VDC | 4 to 500VDC |
Current: | 0 to 60A | 0 to 500A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
A high degree of accuracy is provided via front panel display and computer interfaces. Models are available with relatively wide or narrow current sink ranges. All units have dual ranges for both current and resistance, providing excellent resolution.
ELP-33500F
High Current High Power DC Load
Min | Max | |
---|---|---|
Power: | 0 to 2.4kW | 0 to 14.4kW |
Voltage: | 0.7 to 60VDC | 0.7 to 60VDC |
Current: | 0 to 240A | 0 to 1000A |
ELP-33500F
High Current High Power DC Load
Min | Max | |
---|---|---|
Power: | 0 to 2.4kW | 0 to 14.4kW |
Voltage: | 0.7 to 60VDC | 0.7 to 60VDC |
Current: | 0 to 240A | 0 to 1000A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
Constant current, resistance, voltage and power modes are all standard. When operated in CC or CP modes the loads provide true dynamic functionality, enabling real world pulsing loads to be simulated. Dual ranges are provided for current rise and fall times.
ELP-3360F
High Voltage DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 600W | 0 to 5.4kW |
Voltage: | 4 to 500VDC | 4 to 500VDC |
Current: | 0 to 12A | 0 to 180A |
ELP-3360F
High Voltage DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 600W | 0 to 5.4kW |
Voltage: | 4 to 500VDC | 4 to 500VDC |
Current: | 0 to 12A | 0 to 180A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
The front panel features an isolated BNC output so that the load current can be monitored on an external scope. The high accuracy 5 digit displays features 16 bit resolution. Dual setting ranges provide excellent measurement accuracy at low current.
ELP-3350F
High Current DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 600W | 0 to 1.8kW |
Voltage: | 0.6 to 60VDC | 0.6 to 60VDC |
Current: | 0 to 120A | 0 to 360A |
ELP-3350F
High Current DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 600W | 0 to 1.8kW |
Voltage: | 0.6 to 60VDC | 0.6 to 60VDC |
Current: | 0 to 120A | 0 to 360A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
The unit can be set to operate in constant current, resistance, voltage and power operating modes. A large front panel display shows voltage, current and power simultaneously. True dynamic operation is available in CC & CP modes.
ELP-3310F
Dynamic DC Electronic Load Modules
Min | Max | |
---|---|---|
Power: | 0 to 75W | 0 to 300W |
Voltage: | 0.6 to 60VDC | 6 to 500VDC |
Current: | 0 to 12A | 0 to 60A |
ELP-3310F
Dynamic DC Electronic Load Modules
Min | Max | |
---|---|---|
Power: | 0 to 75W | 0 to 300W |
Voltage: | 0.6 to 60VDC | 6 to 500VDC |
Current: | 0 to 12A | 0 to 60A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
These dynamic single channel modules offer an incredible degree of functionality at a very reasonable cost. Constant current, resistance, voltage and power modes are standard. Dual ranges for CC and CR modes enables tight resolution at the lower end.
ELP-3340G
LED Driver Testing Load
Min | Max | |
---|---|---|
Power: | 0 to 150W | 0 to 300W |
Voltage: | 3 to 300VDC | 6 to 500VDC |
Current: | 0 to 6A | 0 to 24A |
ELP-3340G
LED Driver Testing Load
Min | Max | |
---|---|---|
Power: | 0 to 150W | 0 to 300W |
Voltage: | 3 to 300VDC | 6 to 500VDC |
Current: | 0 to 6A | 0 to 24A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
A specialised LED mode is provided to test LED drivers and power supplies. The load can also be used to simulate a single LED, or a string containing up to 90 LEDs. This is in addition to the standard constant current, resistance, voltage and power operating modes.
ELP-3330F
High Voltage DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 40W | 0 to 250W |
Voltage: | 0.3 to 80VDC | 0.8 to 80VDC |
Current: | 0 to 3A | 0 to 60A |
ELP-3330F
High Voltage DC Loads
Min | Max | |
---|---|---|
Power: | 0 to 40W | 0 to 250W |
Voltage: | 0.3 to 80VDC | 0.8 to 80VDC |
Current: | 0 to 3A | 0 to 60A |
Standard Control: | HMI |
---|---|
Optional Control: | Ethernet, IEEE 488.2, RS-232, USB |
Two independently adjustable load channels are provided in one module. Each channel has CC, CR, CV & CP operating modes along with a programmable short test function. A 5 digit high resolution display shows V, I & P simultaneously for both channels.