G5-CYCLER-HC
High Current Modular Battery Cyclers
G5-CYCLER-HC
High Current Modular Battery Cyclers
With the ability to provide charge/discharge currents into the kiloamp range, the G5-CYCLER-HC is ideal for cycling hybrid energy storage devices.
| Min | Max | |
|---|---|---|
| Power: | 0 to 9kW | 0 to 6MW This maximum is achieved by using units in master-slave. |
| Voltage: | 0 to 60VDC 60V SELV modules are optionally available. | 0 to 1280VDC Configurations >640V are possible with a centre tapped earth. |
| Current: | 0 to ±338A | 0 to ±121680A This maximum is achieved by using units in master-slave. |
| Standard Control: | Analogue, CAN, Ethernet, USB |
|---|---|
| Optional Control: | Touchscreen HMI, EtherCAT |
or call 01246 452909 to discuss this product
Product Information
The G5-CYCLER-HC is able to perform charge/discharge cycles into the kiloamp range, ideal for the testing hybrid vehicles batteries. Modules are stackable to 6MW with mains recycling.
A mechanical interlock is standard with each power dense module. Automatic voltage matching is provided, perfect for testing energy storage devices without an automatic voltage matching circuit. Adjustable power and resistance limits are provided. Every G5-CYCLER-HC features an autoranging output, which allows for many more V/I combinations at nominal power. Modules can be fitted into flight cases or lab racks, with available options including isolation monitoring and emergency stops.
- Programmable Ripple up to 10kHz
- Two Current Ranges for Higher Accuracy
- Mixed Power Nominals in Master-Slave
- Optional Battery Cycling Software
- Ultra-Fast Dynamic Behaviour
- Sink Voltages up to 1280V
Technical Specifications
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
APPLICATION SPECIFIC GUIs
Safety and Protection
Mechanical
Form Factor and Enclosures
Rental Systems
Selection Table
| Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | Internal Resistance Range | |
|---|---|---|---|---|---|---|
| G5-CYCLER 9-80-338 | 9kW | 0 to 80VDC | 1 to 80VDC | 0 to ±338A | 0 to 473mΩ | Add |
| G5-CYCLER 18-80-676 | 18kW | 0 to 80VDC | 1 to 80VDC | 0 to ±676A | 0 to 237mΩ | Add |
| G5-CYCLER 18-160-338 | 18kW | 0 to 160VDC | 2 to 160VDC | 0 to ±338A | 0 to 947mΩ | Add |
| G5-CYCLER 27-80-1014 | 27kW | 0 to 80VDC | 1 to 80VDC | 0 to ±1014A | 0 to 158mΩ | Add |
| G5-CYCLER 27-240-338 | 27kW | 0 to 240VDC | 3 to 240VDC | 0 to ±338A | 0 to 1420mΩ | Add |
| G5-CYCLER 36-80-1352 | 36kW | 0 to 80VDC | 1 to 80VDC | 0 to ±1352A | 0 to 118mΩ | Add |
| G5-CYCLER 36-160-676 | 36kW | 0 to 160VDC | 2 to 160VDC | 0 to ±676A | 0 to 473mΩ | Add |
| G5-CYCLER 36-320-338 | 36kW | 0 to 320VDC | 4 to 320VDC | 0 to ±338A | 0 to 1893mΩ | Add |
| G5-CYCLER 45-80-1690 | 45kW | 0 to 80VDC | 1 to 80VDC | 0 to ±1690A | 0 to 95mΩ | Add |
| G5-CYCLER 54-80-2028 | 54kW | 0 to 80VDC | 1 to 80VDC | 0 to ±2028A | 0 to 79mΩ | Add |
| G5-CYCLER 54-160-1014 | 54kW | 0 to 160VDC | 2 to 160VDC | 0 to ±1014A | 0 to 316mΩ | Add |
| G5-CYCLER 54-240-676 | 54kW | 0 to 240VDC | 3 to 240VDC | 0 to ±676A | 0 to 710mΩ | Add |
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.
G5-CYCLER-HC modules can be arranged in series, parallel or matrix array configurations up to 6MW. Each module is able to operate independently. It is possible to connect models with different nominal powers in an asymmetric parallel configuration, as long as each module has the same nominal voltage. For example, an 18kW/80V/±675A and 54kW/80V/±2028A module can be connected together to in parallel to create a 72kW/80V/±2703A system.
By utilising the optional embedded function generator the user can set a current ripple at up to 10kHz. The magnitude can be up to 5% of the nominal system current. Depending on the impedance of the DUT the resulting voltage ripple can be calculated. The below example shows a 10kHz ripple generated using the function generator of the G5-CYCLER-HC. A peak to peak current of 8A has been superimposed on a current of 100A. Alternatively, a ripple can be implemented from an external waveform generator via the analogue interface using a proportional 0-10V signal.
A current step between 90% sourcing to 90% sinking current can be as quick as 50µs, enabling high speed drives to be supplied. Advanced users have access to the controller settings enabling the response to be optimised for particular loads. The example shows a current step through quadrants.
Every G5-CYCLER-HC features an autoranging output. This allows many more voltage/current combinations at nominal power than a traditional bidirectional DC power system. An example of the difference is shown below using a G5-CYCLER 54-80-2028.
As standard the front panel has backlit indicators which illuminate to show which control mode the battery cycler is operating in (CV, CC, CP, CR). When the G5-CYCLER-HC has been successfully energised, the corresponding power light illuminates green to indicate this. An illumination is also provided to visually warn users of any status (yellow) or error (red) message.
The optional HMI provides a simple and intuitive way of control and measurement via a touchscreen panel. Users can directly access features such as the system's protections, warnings/errors and optional function generator without the use of a computer. A user defined passcode can be set to lock the touch screen, which prevents unauthorised access. When selected, the HMI replaces the front panel indicator.
All G5-CYCLER-HC units come with a simple and intuitive G5.Control operating GUI as standard. Live values of the power system are displayed graphically along with any warning and error messages. The software provides a variety of second level parameters, ideal for users who like to optimise their test processes. In standard user mode the operator can remotely program set values, enable voltage output as well as the ability to analyse different variables including set and actual values via the integrated scope.

The G5-CYCLER-HC modules are designed to be operated within a clean laboratory environment. If there is the possibly that the environment will be less clean, then the optional front panel frame and air filter arrangement offer some additional protection. The standard filter material is rated in class G3. This class is effective at trapping a high proportion (90%) of particles ≥10um according to EN 779.