G5-BATSIM-HC
High Current Modular Battery Emulators
G5-BATSIM-HC
High Current Modular Battery Emulators
With the ability to source or sink up to 89kA, the G5-BATSIM-HC is ideal emulating low voltage high current energy storage devices.
Min | Max | |
---|---|---|
Power: | 0 to 9kW | 0 to 6MW This maximum is achieved by using units in master-slave. |
Voltage: | 0 to 60VDC 60V SELV modules are optionally available. | 0 to 1280VDC Configurations >640V are possible with a centre tapped earth. |
Current: | 0 to ±338A | 0 to ±121680A This maximum is achieved by using units in master-slave. |
Standard Control: | Analogue, Ethernet, USB |
---|---|
Optional Control: | Touchscreen HMI, CAN, EtherCAT |
or call +44 (0)1246 452909 to discuss this product
Product Information
With the ability to source or sink up to 89kA, the G5-BATSIM-HC is ideal emulating low voltage high current energy storage devices. Modules are stackable to 5MW with mains recycling.
Adjustable power and resistance limits are provided to replicate an aging battery pack. An advanced emulation software package is included with every master module, to accurately simulate the electrical characteristics of different chemistry battery packs. Users can user can set a current ripple at up to 10kHz, ideal for EIS research. Each unit also includes programmable PI parameters and an inbuilt 8 channel recording scope. On request modules can be fitted into flight cases or lab racks.
- Advanced Battery Emulation Software
- Two Current Ranges for Higher Accuracy
- Mixed Power Nominals in Master-Slave
- Programmable Ripple up to 10kHz
- Ultra-Fast Dynamic Behaviour
- Sink Voltages up to 1280V
Technical Specifications
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
OPTIONAL APPLICATION GUIs
Safety and Protection
Mechanical
Form Factor and Enclosures
Rental Systems
Selection Table
Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | Internal Resistance Range | |
---|---|---|---|---|---|---|
G5-BATSIM 9-80-338 | 9kW | 0 to 80VDC | 1 to 80VDC | 0 to ±338A | 0 to 473mΩ | Add |
G5-BATSIM 18-80-676 | 18kW | 0 to 80VDC | 1 to 80VDC | 0 to ±676A | 0 to 237mΩ | Add |
G5-BATSIM 18-160-338 | 18kW | 0 to 160VDC | 2 to 160VDC | 0 to ±338A | 0 to 947mΩ | Add |
G5-BATSIM 27-80-1014 | 27kW | 0 to 80VDC | 1 to 80VDC | 0 to ±1014A | 0 to 158mΩ | Add |
G5-BATSIM 27-240-338 | 27kW | 0 to 240VDC | 3 to 240VDC | 0 to ±338A | 0 to 1420mΩ | Add |
G5-BATSIM 36-80-1352 | 36kW | 0 to 80VDC | 1 to 80VDC | 0 to ±1352A | 0 to 118mΩ | Add |
G5-BATSIM 36-160-676 | 36kW | 0 to 160VDC | 2 to 160VDC | 0 to ±676A | 0 to 473mΩ | Add |
G5-BATSIM 36-320-338 | 36kW | 0 to 320VDC | 4 to 320VDC | 0 to ±338A | 0 to 1893mΩ | Add |
G5-BATSIM 45-80-1690 | 45kW | 0 to 80VDC | 1 to 80VDC | 0 to ±1690A | 0 to 95mΩ | Add |
G5-BATSIM 54-80-2028 | 54kW | 0 to 80VDC | 1 to 80VDC | 0 to ±2028A | 0 to 79mΩ | Add |
G5-BATSIM 54-160-1014 | 54kW | 0 to 160VDC | 2 to 160VDC | 0 to ±1014A | 0 to 316mΩ | Add |
G5-BATSIM 54-240-676 | 54kW | 0 to 240VDC | 3 to 240VDC | 0 to ±676A | 0 to 710mΩ | Add |
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.