G5-BATSIM-HC

High Current Modular Battery Emulators

G5-BATSIM-HC

High Current Modular Battery Emulators

With the ability to source or sink up to 89kA, the G5-BATSIM-HC is ideal emulating low voltage high current energy storage devices.

Read more

Min Max
Power: 0 to 9kW 0 to 6MW This maximum is achieved by using units in master-slave.
Voltage: 0 to 60VDC 60V SELV modules are optionally available. 0 to 1280VDC Configurations >640V are possible with a centre tapped earth.
Current: 0 to ±338A 0 to ±121680A This maximum is achieved by using units in master-slave.
Standard Control:Analogue, Ethernet, USB
Optional Control:Touchscreen HMI, CAN, EtherCAT

View more technical data

or call +44 (0)1246 452909 to discuss this product

Product Information

With the ability to source or sink up to 89kA, the G5-BATSIM-HC is ideal emulating low voltage high current energy storage devices. Modules are stackable to 5MW with mains recycling.

Adjustable power and resistance limits are provided to replicate an aging battery pack. An advanced emulation software package is included with every master module, to accurately simulate the electrical characteristics of different chemistry battery packs. Users can user can set a current ripple at up to 10kHz, ideal for EIS research. Each unit also includes programmable PI parameters and an inbuilt 8 channel recording scope. On request modules can be fitted into flight cases or lab racks.

  • Advanced Battery Emulation Software
  • Two Current Ranges for Higher Accuracy
  • Mixed Power Nominals in Master-Slave
  • Programmable Ripple up to 10kHz
  • Ultra-Fast Dynamic Behaviour
  • Sink Voltages up to 1280V

Technical Specifications

Modularity (Master/Slave)

Operating Ranges and Features

Operating Modes

Input

Interfaces and Control

Software/Soft Tools

OPTIONAL APPLICATION GUIs

Safety and Protection

Mechanical

Form Factor and Enclosures

Rental Systems

Selection Table

Part
Number
Nominal PowerSource Voltage Q1Sink Voltage Q4Current RangeInternal Resistance Range
G5-BATSIM 9-80-3389kW0 to 80VDC1 to 80VDC0 to ±338A0 to 473mΩ Add
G5-BATSIM 18-80-67618kW0 to 80VDC1 to 80VDC0 to ±676A0 to 237mΩ Add
G5-BATSIM 18-160-33818kW0 to 160VDC2 to 160VDC0 to ±338A0 to 947mΩ Add
G5-BATSIM 27-80-101427kW0 to 80VDC1 to 80VDC0 to ±1014A0 to 158mΩ Add
G5-BATSIM 27-240-33827kW0 to 240VDC3 to 240VDC0 to ±338A0 to 1420mΩ Add
G5-BATSIM 36-80-135236kW0 to 80VDC1 to 80VDC0 to ±1352A0 to 118mΩ Add
G5-BATSIM 36-160-67636kW0 to 160VDC2 to 160VDC0 to ±676A0 to 473mΩ Add
G5-BATSIM 36-320-33836kW0 to 320VDC4 to 320VDC0 to ±338A0 to 1893mΩ Add
G5-BATSIM 45-80-169045kW0 to 80VDC1 to 80VDC0 to ±1690A0 to 95mΩ Add
G5-BATSIM 54-80-202854kW0 to 80VDC1 to 80VDC0 to ±2028A0 to 79mΩ Add
G5-BATSIM 54-160-101454kW0 to 160VDC2 to 160VDC0 to ±1014A0 to 316mΩ Add
G5-BATSIM 54-240-67654kW0 to 240VDC3 to 240VDC0 to ±676A0 to 710mΩ Add