LAB-GSS
High Current PSU with DC Load Functions
LAB-GSS
High Current PSU with DC Load Functions
Every LAB-GSS module has an extensive feature set which includes an inbuilt 8 channel recording scope and adjustable internal resistance.
| Min | Max | |
|---|---|---|
| Power: | 0 to 32kW | 0 to 64kW |
| Voltage: | 0 to 65VDC | 0 to 65VDC |
| Current: | 0 to 600A | 0 to 1200A |
| Standard Control: | Model Specific |
|---|---|
| Enclosure: | Flightcase |
or call 01246 452909 to discuss this product
Product Information
Every LAB-GSS module has an extensive feature set which includes an inbuilt 8 channel recording scope and adjustable internal resistance. RS-232 and analogue interfaces are provided with every module for remote control. A high speed 1kHz CAN interface is installed with selected models, which is particularly popular in automotive research.
Each module also functions as a fully programmable electronic load. This makes the LAB-GSS ideal for researching devices with bidirectional DC power flows. When functioning as a load, the unit recycles DC sink energy back to the grid, with typical losses of around 7%. This is in contrast to conventional electronic loads which waste 100% of electrical energy that could be reused, by simply dissipating it as heat.
- Mains Regeneration of the DC Sink Energy
- Excellent GUI with Built-in Scope Function
- Function Generator with V/I Capability
- Battery Cycling and Emulation Software
- Adjustable Internal Resistance
Technical Specifications
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
APPLICATION SPECIFIC GUIs
Form Factor and Enclosures
New Systems
Product Applications
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.
The VLS allows the LAB-GSS's output relays to be activated automatically when specific output values are met, protecting the DUT from any damaging charge conditions. Output voltage, current and power values which exceed or fall below a given limit or operating window can be programmed to trigger the relays. Active and inactive areas of operation are defined by a limit value, hysteresis value or a directional designator for the hysteresis.

BatSim provides a convenient method for the LAB-GSS to emulate different sized battery stacks. Nearly all relevant electrical characteristics are programmable, including the number of cells, energy capacity, cut off limits, chemistry type and nominal voltage.
Drive cycle tests can be implemented using BatControl. Previous data obtained from a test track can be imported and recreated, allowing the LAB-GSS to simulate a real world driving test inside a lab environment. Battery and capacitor charge/discharge profiles can also be implemented through the GUI.
The bidirectional characteristics of a real capacitor stack can be emulated when CapSim is installed with LAB-GSS modules. Number of cells in series/parallel, state of charge, cell cut off limits, dynamic capacitance and resistance are programmable.
SASControl software has all EN 50530 tests pre-installed. The GUI allows users to edit irradiance, temperature and amplitude values. Previous tests have been conducted using over 400,000 invividual data points, with more possible.
65V LAB-GSS modules can perform a number of ISO 16750-2 tests. The embedded function generator allows the modules to implement the voltage/time relationships which many of the strict standards require. Specific Tests which can be performed include:
Electrical components within a vehicle's subsystem must be able to withstand a wide range of input voltage surges and drops during a start-up. The LAB-GSS can accurately recreate these conditions within a lab environment. This increases reproducibility and accuracy of results when compared to using real batteries.
In electronic systems sudden voltage interruptions may cause unexpected behaviour. Supply line disturbances may have several causes, including an additional switch on of large capacitive loads parallel to the supply line or a short circuit caused by loads sharing the supply. The LAB-GSS can generate many complex DC waveforms to test devices under realistic conditions to identify any potential issues.