LAB-SCUBI-SIM
High Power Battery Emulator
LAB-SCUBI-SIM
High Power Battery Emulator
High dynamics enable users to switch seamlessly between simulating a charging or discharging battery. Each LAB-SCUBI-SIM has an extremely wide operating range.
| Min | Max | |
|---|---|---|
| Power: | 0 to 60kW | 0 to 1.3MW This maximum is achieved by using units in master-slave. |
| Voltage: | 0 to 300VDC | 0 to 1000VDC |
| Current: | 0 to ±200A | 0 to ±2000A This maximum is achieved by using units in master-slave. |
| Standard Control: | Touchscreen HMI, CAN, Ethernet, MODBUS |
|---|---|
| Optional Control: | Analogue, PROFIBUS, PROFINET |
or call 01246 452909 to discuss this product
Product Information
The LAB-SCUBI-SIM is a series of high power battery emulators. Each system is able to operate as either a DC source or a DC electronic load.
This integrated approach features high dynamics enabling the user to switch seamlessly between quadrants. When sinking energy from the unit under test the LAB-SCUBI-SIM automatically inverts the DC to AC and synchronises this output to the grid. An extended feature set includes voltage and current ripple below 0.1%, sense terminals for voltage drop compensation as well as a range of protection features.
- Dedicated Battery Emulation Mode
- Seamless Transition Between Source/Sink
- Nominal Outputs up to 1000V/±1000A
- Lowest Life Component 60,000h
- High Dynamics and Stability
Technical Specifications
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
Safety and Protection
Mechanical
Form Factor and Enclosures
Rental Systems
Selection Table
60kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 300-60-200 | 60kW | 0 - 300V | 0 to ±200A | Add |
| LAB-SCUBI-SIM 300-60-600 | 60kW | 0 - 300V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 300-60-1000 | 60kW | 0 - 300V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 600-60-200 | 60kW | 0 - 600V | 0 to ±200A | Add |
| LAB-SCUBI-SIM 600-60-600 | 60kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-60-200 | 60kW | 0 - 1000V | 0 to ±200A | Add |
100kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 600-100-200 | 100kW | 0 - 600V | 0 to ± to 200A | Add |
| LAB-SCUBI-SIM 600-100-600 | 100kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 600-100-1000 | 100kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 800-100-200 | 100kW | 0 - 800V | 0 to ±200A | Add |
| LAB-SCUBI-SIM 800-100-600 | 100kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 800-100-1000 | 100kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 1000-100-200 | 100kW | 0 - 1000V | 0 to ±200A | Add |
| LAB-SCUBI-SIM 1000-100-600 | 100kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-100-1000 | 100kW | 0 - 1000V | 0 to ±1000A | Add |
120kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 300-120-600 | 120kW | 0 - 300V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 300-120-1000 | 120kW | 0 - 300V | 0 to ±1000A | Add |
160kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 300-160-1000 | 160kW | 0 - 300V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 600-160-600 | 160kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 600-160-1000 | 160kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 800-160-200 | 160kW | 0 - 800V | 0 to ±200A | Add |
| LAB-SCUBI-SIM 800-160-600 | 160kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 800-160-1000 | 160kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 1000-160-200 | 160kW | 0 - 1000V | 0 to ±200A | Add |
| LAB-SCUBI-SIM 1000-160-600 | 160kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-160-1000 | 160kW | 0 - 1000V | 0 to ±1000A | Add |
250kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 600-250-600 | 250kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 600-250-1000 | 250kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 800-250-600 | 250kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 800-250-1000 | 250kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 1000-250-600 | 250kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-250-1000 | 250kW | 0 - 1000V | 0 to ±1000A | Add |
320kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 600-320-600 | 320kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 600-320-1000 | 320kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 800-320-600 | 320kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 800-320-1000 | 320kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 1000-320-600 | 320kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-320-1000 | 320kW | 0 - 1000V | 0 to ±1000A | Add |
400kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 600-400-1000 | 400kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 800-400-1000 | 400kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 1000-400-600 | 400kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-400-1000 | 400kW | 0 - 1000V | 0 to ±1000A | Add |
500kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 600-500-1000 | 500kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 800-500-1000 | 500kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI-SIM 1000-500-600 | 500kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI-SIM 1000-500-1000 | 500kW | 0 - 1000V | 0 to ±1000A | Add |
650kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI-SIM 1000-650-1000 | 650kW | 0 - 1000V | 0 to ±1000A | Add |
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.



Each LAB-SCUBI-SIM features constant power, constant current, constant voltage and internal resistance operation. As standard the power system operates in battery simulation mode (/SIM) instead of the standard battery tester mode. This is ideal for testing battery power components and provides users with the benefits of:
Where you require to both test and emulate batteries, the system can be installed with both operating modes (/SIM-TEST), which are user switchable between the two. The battery tester mode provides users with the benefits of: