| Min | Max | |
|---|---|---|
| Power: | 0 to 60kW | 0 to 1.3MW This maximum is achieved by using units in master-slave. |
| Voltage: | 0 to 300VDC | 0 to 1000VDC |
| Current: | 0 to ±200A | 0 to ±2000A This maximum is achieved by using units in master-slave. |
| Standard Control: | Touchscreen HMI, CAN, Ethernet, MODBUS |
|---|---|
| Optional Control: | Analogue, PROFIBUS, PROFINET |
or call 01246 452909 to discuss this product
Product Information
The LAB-SCUBI is a series of high power battery test systems. Each system is bidirectional and able to implement battery charge/discharge cycles.
This integrated approach features high dynamics enabling the user to switch seamlessly between charging and discharging. When sinking energy from the energy storage device under test the LAB-SCUBI automatically inverts the DC to AC and synchronises this output to the grid. An extended feature set includes voltage and current ripple below 0.1%, sense terminals for voltage drop compensation as well as a range of protection features.
- Seamless Transition Between Source/Sink
- Nominal Outputs up to 1000V/±1000A
- Extremely Wide Operating Ranges
- Lowest Life Component 60,000h
- High Dynamics and Stability
Technical Specifications
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
Safety and Protection
Mechanical
Form Factor and Enclosures
Rental Systems
Selection Table
60kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 300-60-200 | 60kW | 0 - 300V | 0 to ±200A | Add |
| LAB-SCUBI 300-60-600 | 60kW | 0 - 300V | 0 to ±600A | Add |
| LAB-SCUBI 300-60-1000 | 60kW | 0 - 300V | 0 to ±1000A | Add |
| LAB-SCUBI 600-60-200 | 60kW | 0 - 600V | 0 to ±200A | Add |
| LAB-SCUBI 600-60-600 | 60kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI 1000-60-200 | 60kW | 0 - 1000V | 0 to ±200A | Add |
100kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 600-100-200 | 100kW | 0 - 600V | 0 to ±200A | Add |
| LAB-SCUBI 600-100-600 | 100kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI 600-100-1000 | 100kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI 800-100-200 | 100kW | 0 - 800V | 0 to ±200A | Add |
| LAB-SCUBI 800-100-600 | 100kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI 800-100-1000 | 100kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI 1000-100-200 | 100kW | 0 - 1000V | 0 to ±200A | Add |
| LAB-SCUBI 1000-100-600 | 100kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI 1000-100-1000 | 100kW | 0 - 1000V | 0 to ±1000A | Add |
120kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 300-120-600 | 120kW | 0 - 300V | 0 to ±600A | Add |
| LAB-SCUBI 300-120-1000 | 120kW | 0 - 300V | 0 to ±1000A | Add |
160kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 300-160-1000 | 160kW | 0 - 300V | 0 to ±1000A | Add |
| LAB-SCUBI 600-160-600 | 160kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI 600-160-1000 | 160kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI 800-160-200 | 160kW | 0 - 800V | 0 to ±200A | Add |
| LAB-SCUBI 800-160-600 | 160kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI 800-160-1000 | 160kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI 1000-160-200 | 160kW | 0 - 1000V | 0 to ±200A | Add |
| LAB-SCUBI 1000-160-600 | 160kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI 1000-160-1000 | 160kW | 0 - 1000V | 0 to ±1000A | Add |
250kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 600-250-600 | 250kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI 600-250-1000 | 250kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI 800-250-600 | 250kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI 800-250-1000 | 250kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI 1000-250-600 | 250kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI 1000-250-1000 | 250kW | 0 - 1000V | 0 to ±1000A | Add |
320kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 600-320-600 | 320kW | 0 - 600V | 0 to ±600A | Add |
| LAB-SCUBI 600-320-1000 | 320kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI 800-320-600 | 320kW | 0 - 800V | 0 to ±600A | Add |
| LAB-SCUBI 800-320-1000 | 320kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI 1000-320-600 | 320kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI 1000-320-1000 | 320kW | 0 - 1000V | 0 to ±1000A | Add |
400kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 600-400-1000 | 400kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI 800-400-1000 | 400kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI 1000-400-600 | 400kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI 1000-400-1000 | 400kW | 0 - 1000V | 0 to ±1000A | Add |
500kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 600-500-1000 | 500kW | 0 - 600V | 0 to ±1000A | Add |
| LAB-SCUBI 800-500-1000 | 500kW | 0 - 800V | 0 to ±1000A | Add |
| LAB-SCUBI 1000-500-600 | 500kW | 0 - 1000V | 0 to ±600A | Add |
| LAB-SCUBI 1000-500-1000 | 500kW | 0 - 1000V | 0 to ±1000A | Add |
650kW MODELS
| Part Number |
Nominal Power | Voltage Range | Current Range | |
|---|---|---|---|---|
| LAB-SCUBI 1000-650-1000 | 650kW | 0 - 1000V | 0 to ±1000A | Add |
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.



Each LAB-SCUBI features constant power, constant current, constant power and internal resistance operation. As standard the power system operates in battery testing mode. This is ideal for testing battery power components and provides users with the benefits of:
Where you require to both test and emulate batteries, the system can be installed with both operating modes (/SIM-TEST), which are user switchable between the two. The battery simulation mode provides users with the benefits of: