LAB-GSS
High Current Modular Battery Cyclers
LAB-GSS
High Current Modular Battery Cyclers
Up to 64 LAB-GSS modules can be configured in series, parallel or matrix up to 2MW/1500V. Allowing a wide variety of batteries to be tested.
| Min | Max | |
|---|---|---|
| Power: | 0 to 20kW | 0 to 2MW This maximum is achieved by using units in master-slave. |
| Voltage: | 0 to 65VDC | 0 to 1500VDC This maximum is achieved by using units in master-slave. |
| Current: | 0 to ±40A | 0 to ±38400A This maximum is achieved by using units in master-slave. |
| Standard Control: | Analogue, RS-232 |
|---|---|
| Optional Control: | HMI, CAN, Ethernet, IEEE 488.2, Optolink, RS-422, USB |
or call 01246 452909 to discuss this product
Product Information
The LAB-GSS is a bidirectional battery cycler able to implement charge/discharge cycles. This integrated approach features high dynamics enabling users to switch quickly between quadrants.
When sinking energy from the energy storage device under test, the LAB-GSS automatically inverts the DC to AC and synchronises this output to the grid. A variety of control methods are available. As standard each module is built with isolated analogue and RS-232 interfaces. Front panel control and display along with IEEE 488.2 (GPIB), USB, RS-422, CAN & Ethernet interfaces are optionally available. An optional battery cycling GUI is available as well as a function generator, allowing users to implement complex tests.
- Stackable up to 1500V/Very High Powers
- Mains Regeneration of the DC Sink Energy
- Excellent GUI with Built-in Scope Function
- Function Generator with V/I Capability
- Optional Battery Cycling Software
- Adjustable Internal Resistance
Technical Specifications
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
APPLICATION SPECIFIC GUIs
Safety and Protection
Mechanical
Form Factor and Enclosures
Rental Systems
Selection Table
65V Module Configurations
| Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | |
|---|---|---|---|---|---|
| LAB-GSS 20-65 | 20kW | 0 - 65VDC | 6 - 65VDC | 0 to ±385A | Add |
| LAB-GSS 32-65 | 32kW | 0 - 65VDC | 6 - 65VDC | 0 to ±600A | Add |
| LAB-GSS 20-65-2 | 40kW | 0 - 130VDC | 6 - 130VDC | 0 to ±770A | Add |
| LAB-GSS 32-65-2 | 64kW | 0 - 130VDC | 6 - 130VDC | 0 to ±1200A | Add |
| LAB-GSS 32-65-3 | 96kW | 0 - 195VDC | 6 - 195VDC | 0 to ±1800A | Add |
| LAB-GSS 32-65-4 | 128kW | 0 - 260VDC | 6 - 260VDC | 0 to ±2400A | Add |
| LAB-GSS 32-65-8 | 256kW | 0 - 520VDC | 6 - 520VDC | 0 to ±4800A | Add |
130V Module Configurations
| Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | |
|---|---|---|---|---|---|
| LAB-GSS 20-130 | 20kW | 0 - 130VDC | 12 - 130VDC | 0 to ±192A | Add |
| LAB-GSS 32-130 | 32kW | 0 - 130VDC | 12 - 130VDC | 0 to ±308A | Add |
| LAB-GSS 20-130-2 | 40kW | 0 - 260VDC | 12 - 260VDC | 0 to ±384A | Add |
| LAB-GSS 32-130-2 | 64kW | 0 - 260VDC | 12 - 260VDC | 0 to ±616A | Add |
| LAB-GSS 32-130-3 | 96kW | 0 - 390VDC | 12 - 390VDC | 0 to ±924A | Add |
| LAB-GSS 32-130-4 | 128kW | 0 - 520VDC | 12 - 520VDC | 0 to ±1232A | Add |
| LAB-GSS 32-130-8 | 256kW | 0 - 1040VDC | 12 - 1040VDC | 0 to ±2464A | Add |
400V Module Configurations
| Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | |
|---|---|---|---|---|---|
| LAB-GSS 20-400 | 20kW | 0 - 400VDC | 50 - 400VDC | 0 to ±63A | Add |
| LAB-GSS 32-400 | 32kW | 0 - 400VDC | 50 - 400VDC | 0 to ±100A | Add |
| LAB-GSS 20-400-2 | 40kW | 0 - 800VDC | 50 - 800VDC | 0 to ±126A | Add |
| LAB-GSS 32-400-2 | 64kW | 0 - 800VDC | 50 - 800VDC | 0 to ±200A | Add |
| LAB-GSS 32-400-3 | 96kW | 0 - 1200VDC | 50 - 1200VDC | 0 to ±300A | Add |
| LAB-GSS 32-400-4 | 128kW | 0 - 1500VDC | 50 - 1500VDC | 0 to ±400A | Add |
| LAB-GSS 32-400-8 | 256kW | 0 - 1500VDC | 50 - 1500VDC | 0 to ±800A | Add |
500V Module Configurations
| Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | |
|---|---|---|---|---|---|
| LAB-GSS 20-500 | 20kW | 0 - 500VDC | 40 - 500VDC | 0 to ±50A | Add |
| LAB-GSS 32-500 | 32kW | 0 - 500VDC | 40 - 500VDC | 0 to ±80A | Add |
| LAB-GSS 20-500-2 | 40kW | 0 - 1000VDC | 40 - 1000VDC | 0 to ±100A | Add |
| LAB-GSS 32-500-2 | 64kW | 0 - 1000VDC | 40 - 1000VDC | 0 to ±160A | Add |
| LAB-GSS 32-500-3 | 96kW | 0 - 1500VDC | 40 - 1500VDC | 0 to ±240A | Add |
| LAB-GSS 32-500-4 | 128kW | 0 - 1500VDC | 40 - 1500VDC | 0 to ±320A | Add |
| LAB-GSS 32-500-8 | 256kW | 0 - 1500VDC | 40 - 1500VDC | 0 to ±640A | Add |
600V Module Configurations
| Part Number |
Nominal Power | Source Voltage Q1 | Sink Voltage Q4 | Current Range | |
|---|---|---|---|---|---|
| LAB-GSS 20-600 | 20kW | 0 - 600VDC | 50 - 600VDC | 0 to ± 40A | Add |
| LAB-GSS 32-600 | 32kW | 0 - 600VDC | 50 - 600VDC | 0 to ±66A | Add |
| LAB-GSS 20-600-2 | 40kW | 0 - 1200VDC | 50 - 1200VDC | 0 to ±80A | Add |
| LAB-GSS 32-600-2 | 64kW | 0 - 1200VDC | 50 - 1200VDC | 0 to ±132A | Add |
| LAB-GSS 32-600-3 | 96kW | 0 - 1500VDC | 50 - 1500VDC | 0 to ±198A | Add |
| LAB-GSS 32-600-4 | 128kW | 0 - 1500VDC | 50 - 1500VDC | 0 to ±264A | Add |
| LAB-GSS 32-600-8 | 256kW | 0 - 1500VDC | 50 - 1500VDC | 0 to ±528A | Add |
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.
Up to 64 LAB-GSS modules can be arranged in series, parallel or matrix array configurations. Each module is able to operate independently, so that systems can be reconfigured, expanded or broken up as needs dictate. Inbuilt system comms allow users to switch between various set-ups.
All LAB-GSS units come with a simple and intuitive TopControl operating GUI as standard. Live values of the power system are displayed graphically along with any warning and error messages. The software provides a variety of second level parameters, ideal for users who like to optimise their test processes. In standard user mode the operator can remotely program set values, enable voltage output as well as the ability to analyse different variables including set and actual values via the integrated scope.

The standard 19" LAB-GSS rackmounting modules can be treated to a laboratory rack or flight case integration. Common options include mains cables, passive indication of any residual DC voltage, isolation monitoring of DC cables and a panel mounted emergency stop. Switch panels with removable DC links can be fitted for modular systems. This simplifies the reconfiguration between series, parallel or independent use. Simple wheeled cabinets are also available.