RUG-GSX
DC Sources with Low Reflected Harmonics
RUG-GSX
DC Sources with Low Reflected Harmonics
Each modular RUG-GSX power supply features low reflected current harmonics and has an inbuilt active power correction of ≥0.99.
| Min | Max | |
|---|---|---|
| Power: | 0 to 20kW | 0 to 2MW This maximum is achieved by using units in master-slave. |
| Voltage: | 0 to 65VDC | 0 to 1500VDC This maximum is achieved by using units in master-slave. |
| Current: | 0 to 40A | 0 to 38400A This maximum is achieved by using units in master-slave. |
| Standard Control: | Analogue, RS-232 |
|---|---|
| Optional Control: | HMI, CAN, Ethernet, IEEE 488.2, Optolink, RS-422, USB |
or call 01246 452909 to discuss this product
Product Information
The RUG-GSX is ideal for mobile applications where space is at a premium. Each module features low reflected current harmonics and has an inbuilt active power correction of ≥0.99.
The excellent PFC allows for smaller components and cabling to be used throughout the vehicle or vessel. It also allows the RUG-GSX to be powered from a weakly regulated generator. Previous applications have varied from powering towed array and hull mounted sonar systems, to battery charging and powering vehicle transmitters. Low level protocols (LLP) gives access to the most commonly used hexadecimal memory addresses for given functions. A variety of interfaces are available for remote control of the unit.
- Protections for Shock, Vibration & Humidity
- Stackable up to 1500V/Very High Powers
- Function Generator with V/I Capability
- Inbuilt Active Power Correction ≥0.99
- Low Reflected Current Harmonics
- Access to Low Level Protocols
Technical Specifications
Mechanical
Form Factor and Enclosures
Modularity (Master/Slave)
Operating Ranges and Features
Operating Modes
Input
Interfaces and Control
Software/Soft Tools
APPLICATION SPECIFIC GUIs
Safety and Protection
Product Applications
Selection Table
65V Module Configurations
| Part Number |
Max Power | Output Voltage | Output Current | |
|---|---|---|---|---|
| RUG-GSX 20-65 | 20kW | 0 to 65VDC | 0 to 385A | Add |
| RUG-GSX 32-65 | 32kW | 0 to 65VDC | 0 to 600A | Add |
| RUG-GSX 20-65-2 | 40kW | 0 to 130VDC | 0 to 770A | Add |
| RUG-GSX 32-65-2 | 64kW | 0 to 130VDC | 0 to 1200A | Add |
| RUG-GSX 32-65-3 | 96kW | 0 to 195VDC | 0 to 1800A | Add |
| RUG-GSX 32-65-4 | 128kW | 0 to 260VDC | 0 to 2400A | Add |
| RUG-GSX 32-65-8 | 256kW | 0 to 520VDC | 0 to 4800A | Add |
130V Module Configurations
| Part Number |
Max Power | Output Voltage | Output Current | |
|---|---|---|---|---|
| RUG-GSX 20-130 | 20kW | 0 to 130VDC | 0 to 192A | Add |
| RUG-GSX 32-130 | 32kW | 0 to 130VDC | 0 to 308A | Add |
| RUG-GSX 20-130-2 | 40kW | 0 to 260VDC | 0 to 384A | Add |
| RUG-GSX 32-130-2 | 64kW | 0 to 260VDC | 0 to 616A | Add |
| RUG-GSX 32-130-3 | 96kW | 0 to 390VDC | 0 to 924A | Add |
| RUG-GSX 32-130-4 | 128kW | 0 to 520VDC | 0 to 1232A | Add |
| RUG-GSX 32-130-8 | 256kW | 0 to 1040VDC | 0 to 2464A | Add |
400V Module Configurations
| Part Number |
Max Power | Output Voltage | Output Current | |
|---|---|---|---|---|
| RUG-GSX 20-400 | 20kW | 0 to 400VDC | 0 to 63A | Add |
| RUG-GSX 32-400 | 32kW | 0 to 400VDC | 0 to 100A | Add |
| RUG-GSX 20-400-2 | 40kW | 0 to 800VDC | 0 to 126A | Add |
| RUG-GSX 32-400-2 | 64kW | 0 to 800VDC | 0 to 200A | Add |
| RUG-GSX 32-400-3 | 96kW | 0 to 1200VDC | 0 to 300A | Add |
| RUG-GSX 32-400-4 | 128kW | 0 to 1500VDC | 0 to 400A | Add |
| RUG-GSX 32-400-8 | 256kW | 0 to 1500VDC | 0 to 800A | Add |
500V Module Configurations
| Part Number |
Max Power | Output Voltage | Output Current | |
|---|---|---|---|---|
| RUG-GSX 20-500 | 20kW | 0 to 500VDC | 0 to 50A | Add |
| RUG-GSX 32-500 | 32kW | 0 to 500VDC | 0 to 80A | Add |
| RUG-GSX 20-500-2 | 40kW | 0 to 1000VDC | 0 to 100A | Add |
| RUG-GSX 32-500-2 | 64kW | 0 to 1000VDC | 0 to 160A | Add |
| RUG-GSX 32-500-3 | 96kW | 0 to 1500VDC | 0 to 240A | Add |
| RUG-GSX 32-500-4 | 128kW | 0 to 1500VDC | 0 to 320A | Add |
| RUG-GSX 32-500-8 | 256kW | 0 to 1500VDC | 0 to 640A | Add |
600V Module Configurations
| Part Number |
Max Power | Output Voltage | Output Current | |
|---|---|---|---|---|
| RUG-GSX 20-600 | 20kW | 0 to 600VDC | 0 to 40A | Add |
| RUG-GSX 32-600 | 32kW | 0 to 600VDC | 0 to 66A | Add |
| RUG-GSX 20-600-2 | 40kW | 0 to 1200VDC | 0 to 80A | Add |
| RUG-GSX 32-600-2 | 64kW | 0 to 1200VDC | 0 to 132A | Add |
| RUG-GSX 32-600-3 | 96kW | 0 to 1500VDC | 0 to 198A | Add |
| RUG-GSX 32-600-4 | 128kW | 0 to 1500VDC | 0 to 264A | Add |
| RUG-GSX 32-600-8 | 256kW | 0 to 1500VDC | 0 to 528A | Add |
Frequently asked questions
Can't find what you're looking for? Ask us a question
Please fill out the form below and we will get back to you as soon as possible with an answer to your question.
Each RUG-GSX is built into a 19" rackmounting case as standard. Modules can be treated to an integration into a static enclosure or flight case. Common options include mains cables, passive indication of any residual DC voltage, isolation monitoring of DC cables and a panel mounted emergency stop. Switch panels with removable DC links can be fitted for modular systems. This simplifies the reconfiguration between series, parallel or independent use. Simple wheeled cabinets are also available.
Larger systems can be composed of smaller 20kW or 32kW RUG-GSX modules. Up to 64 of these modules can be arranged in series, parallel or matrix array configurations to create larger systems.
The VLS allows the output relays to be activated automatically when specific output values are met, protecting the DUT from any damaging conditions. Output voltage, current and power values which exceed or fall below a given limit or operating window can be programmed to trigger the relays. Active and inactive areas of operation are defined by a limit value, hysteresis value or a directional designator for the hysteresis.
All RUG-GSX units come with a simple and intuitive TopControl operating GUI as standard. Live values of the power system are displayed graphically along with any warning and error messages. The software provides a variety of second level parameters, ideal for users who like to optimise their test processes. In standard user mode the operator can remotely program set values, enable voltage output as well as the ability to analyse different variables including set and actual values via the integrated scope.

The precise nature of sonar systems requires a highly controlled power supply. A poorly regulated PSU may provide too much energy to the sonar system's transducers, which can cause quenching. This is where the water pressure drops so low that it boils, potentially destroying the transducer. The quenching power limit rises with depth due to increased ambient pressure, so the maximum power output needs to be adjusted accordingly.
The RUG-GSX can provide the short and precise DC pulses needed to power on-board transmitters in defence vehicles. Military land vehicles require ultra-reliable power supplies for mission critical electrical equipment. Each RUG-GSX unit has protections for shock, vibration and humidity allowing the power system to operate across rugged terrains.
The RUG-GSX's wide AC input ensures charging is always possible from generators or local grid conditions. An Active Factor Correction (PFC) circuit integrated into the input helps a generator maintain a stable and reliable output.
Applications with long load lines often suffer from unintended voltage drops, such as downhole tools used in hydrocarbon exploration. The RUG-GSX's sense plus allows voltage drops to be compensated for throughout the entire length of a load line. This feature is also ideal for powering subsea devices.