ELPA-3252
DC Load Modules with AC Functions
ELPA-3252
DC Load Modules with AC Functions
This load module features both DC and AC sink functions up to 20A/300V. A front panel memory with an auto sequencing function is provided.
Min | Max | |
---|---|---|
Power: | 0 to 300W | 0 to 300W |
Voltage: | 30 to 300VDC | 30 to 300VDC |
Current: | 0 to 4A | 0 to 4A |
Standard Control: | HMI, IEEE 488.2, RS-232 |
---|---|
Enclosure: | Mainframe |
or call +44 (0)1246 452909 to discuss this product
Product Information
This AC load operates in constant current and resistance modes, with nominal sink values up to 4A or 300V. Waveforms can be recalled or enabled from the front panel or via the computer interface. Dual 4½ digit displays clearly show the voltage and current values at the load terminals.
Remote sense is provided to counter any voltage drops in the load line. An external analogue input enables the ELPA-3252 modules to load according to an external signal. This allows complex waveforms to be set up on a function generator. For batch testing, upper and lower limits can be adjusted to signal a pass or fail.
- One Unit to Sink AC or DC sources
- CC, CR and Crest Factor Mode
- Adjustable Power Factor
- GO/NG Limit Check
- Remote Sense
Technical Specifications
Operating Ranges and Features
Operating Modes
Interfaces and Control
Form Factor and Enclosures
New Systems
Selection Table
Part Number |
Max Power | Voltage Range | Current Range | |
---|---|---|---|---|
ELPA-3252-r | 300W | 30 - 300VDC | 0 - 4A | Add |